By - Jon Brown

SCADA 101: Fundamentals with a Focus on Energy Management System (EMS)
August 3-4, 2020 | Denver, CO

 

Overview

Learn the fundamentals of SCADA systems with focus on Energy Management systems (EMS).

SCADA systems are generally used to monitor and control equipment in industries such as telecommunications, water and waste control, energy, oil and gas refining and transportation – mainly systems that are geographically wide spread.

The course explores the evolution of SCADA systems, learning the differences in the SCADA types and how they evolved from monolithic to distributed to networked. 

This course will explain the typical SCADA hardware components through different view points and how they work together.

  • Hardware standpoint: administrator, data acquisition servers and front-end processors redundancies
  • Security standpoint: for Primary and backup system
  • Data maintenance standpoint: Quality control system, production system

There will be an explanation of the data flow all the way from field, through RTU to front end processor to control room and how different telemetry points are processed.  Learn about analogs, status points, accumulators, different ways that they can be collected in field RTU for data exchange, scan rates, and protocols. Discuss how the data can be processed for the end user, alarm processing, switching controls, processing logic in database, and putting it into the dynamic graphic user interface for end to end control and monitoring.

We will explore the best data maintenance practices, such as maintaining the data standards, templates, creating the point list and checkout lists, performing point to point testing, maintaining the quality assurance systems independent from productions where jobs are run first.

The course will talk about data storage in historic servers and how data can be used or replayed. Uses of dispatch training system for the real time data and data analysis for performing various actions to the system and how they affect the systems.

In the end, students should gain solid understanding of how SCADA systems work, how and why they were developed, how they are structured, its database and data collection techniques, and uses of the dynamic data by the end user.

Learning Outcomes

  • Discuss the history and evolution of SCADA Systems
  • Identify the basic hardware and software components of a SCADA system
  • Examine communication protocols that are used to transmit, collect, store and manage data
  • Discuss the increased need for cyber security for ICS
  • Describe different instrumentation measurement technologies
  • Review SCADA system architecture
  • Discuss the data flow from field to control room
  • Identify alarm processing and supervisory control

Credits

AP_Logo

EUCI has been accredited as an Authorized Provider by the International Association for Continuing Education and Training (IACET).  In obtaining this accreditation, EUCI has demonstrated that it  complies with the ANSI/IACET Standard which is recognized internationally as a standard of good practice. As a result of their Authorized Provider status, EUCI is authorized to offer IACET CEUs for its programs that qualify under the ANSI/IACET Standard.

EUCI is authorized by IACET to offer 1.1 CEUs for this event.

 

Requirements for Successful Completion of Program

Participants must sign in/out each day, be in attendance for the entirety of the course

Instructional Methods

Power Point presentations and open discussion will be used

Agenda

Monday, August 3, 2020

registration8:00 – 8:30 a.m. :: Registration and Continental Breakfast

timing8:30 a.m. – 5:00 p.m. :: Course Timing

lunch12:00 p.m. – 1:00 p.m. :: Group Luncheon


Agenda Day 1

  • SCADA Overview
  • SCADA Definition 
  • SCADA History and Evolution
    • By technological evolution
    • Telemetry-based SCADA
    • Minicomputers
    • Microprocessors – PLC
  • SCADA Types 
    • By market evolution
    • Monolithic
    • Distributed
    • Networked
  • SCADA Systems Components
  • Common SCADA Abbreviations
  • Typical Hardware SCADA Architecture
    • Master administrator – data repository
    • Communicator – data acquisition
    • Front end processor – RTU 
    • Historian – data archiving
    • Human Machine Interface – individual users
  • Typical System Division
    • Primary system
    • Backup system
    • Training system (DTS)
  • RTUs
    • RTU protocols types
    • RTU scans rates and options
    • Field devices
  • SCADA Data Collection – Point Types and Uses
    • Analog points (measurements)
      • Limits
      • Setpoints
      • Secondary sources
    • Accumulators (periodic collection)
      • Meter collections
      • Counter values
    • Status points (indication and controls)
      • Alarm processing
      • Supervisory controls
  • Data Collection and Q&A Session
  • Course Adjourns for the day

Tuesday, August 4, 2020

registration8:00 – 8:30 a.m. :: Continental Breakfast

timing8:30 a.m.- 12:00 p.m. :: Course Timing

Agenda Day 2

  • Review of Day 1
  • Data Management
  • Maintaining the Data and Best Practices
    • Constructions project
    • Engineering points list
    • Data standards
    • Safe job processing (QAS and productions systems)
    • Station one-line drawings and dynamic graphic user interface
    • Point to point testing
    • Checklist and procedures
  • SCADA Security and Additional Applications
  • Network Processing 
  • Dispatch Training
  • Cyber Security of SCADA
  • Course Concludes

Instructor

Ivana O’Deen
Principal Database Specialist, Xcel Energy

Ivana O’Deen is a current Principal Database Specialist at Xcel Energy. She has been with Xcel Energy for 12 years where she has been responsible for managing and training employees on SCADA/EMS systems. Prior to her employment at Xcel Energy she worked 11 years for Siemens, EMS division in Minnetonka, MN. During her employment at Siemens she helped prototype numerous client’s database and displays and conducted the in-house training of Siemens Spectrum database and display systems management. 

Location

EUCI Conference Center

6400 S Fiddlers Green Cir.

Greenwood Village CO, 80111

The EUCI conference center is conveniently located adjacent to the Arapahoe at Village Center Light Rail Station, allowing easy access to and from DIA, Downtown, and Local Area Attractions.

Nearby Hotels

Each of these hotels offers a complimentary shuttle to and from the EUCI conference center.

Hyatt Regency Denver Tech Center
7800 East Tufts Ave
Denver, CO 80237
Phone: 1-303-779-1234
2.8 miles away
Special EUCI Room Rate: $179.00
To access EUCI room rate visit denvertechcenter.regency.hyatt.com
Click “Book Now”, then click “Special Rates”
Click “Corporate or Group Code” and enter CR102338
You may also call our central reservation at 1-800-233-1234 and give them the corporate code of CR102338

Double Tree by Hilton DTC
7801 East Orchard Rd.
Greenwood Village, CO 80111
Phone: 303-779-6161
0.5 miles away

Wingate by Wyndham
8000 East Peakview Ave
Greenwood Village, CO 80111
Phone: 303-626-2641
0.3 miles away

Hyatt Place Denver Tech Center
8300 E.Crescent Parkway
Greenwood Village, CO 80111
Phone: 1-303-804-0700
2.1 miles away

Denver Marriott Tech Center
4900 S Syracuse St
Denver, CO 80237
Phone: 303-779-1100
3.1 miles away

Register

EventEarly Bird Before
Friday, July 17, 2020
Standard RateAttendees
SCADA 101: Fundamentals with a Focus on Energy Management System (EMS)US $ 1195.00 US $ 1195.00

By registering I indicate I agree with EUCIs privacy policy and understand I may receive emailed reports, articles, event invitations and other information related to products and services from EUCI and any of our business partners. I understand I may unsubscribe at any time by clicking the link included in emails.

Register 3 Send 4th Free!

Any organization wishing to send multiple attendees to these conferences may send 1 FREE for every 3 delegates registered. Please note that all registrations must be made at the same time to qualify.

Cancellation Policy

Your registration may be transferred to a member of your organization up to 24 hours in advance of the event. Cancellations must be received on or before July 03, 2020 in order to be refunded and will be subject to a US $195.00 processing fee per registrant. No refunds will be made after this date. Cancellations received after this date will create a credit of the tuition (less processing fee) good toward any other EUCI event. This credit will be good for six months from the cancellation date. In the event of non-attendance, all registration fees will be forfeited. In case of conference cancellation, EUCIs liability is limited to refund of the event registration fee only. For more information regarding administrative policies, such as complaints and refunds, please contact our offices at 303-770-8800

By clicking Accept or closing this message, you consent to our cookies on this device in accordance with our cookie policy unless you have disabled them. more information

By clicking Accept or closing this message, you consent to our cookies on this device in accordance with our cookie policy unless you have disabled them. You can change your cookie settings at any time but parts of our site will not function correctly without them. We use cookies during the registration process and to remember member settings.

Close