The electric distribution ground system is a complex network of various paths and accommodates the return current back to the substation. Ohm’s Law tells us that any current passing through an impedance creates a voltage. If we acknowledge that the ground path(s) is not a perfect conductor, we know that stray voltage is inevitable.

This course provides insight into the workings of the grounding system from the end user back to the substation. Attendees learn the causes of high ground currents, how they can be minimized, and the techniques to mitigating stray voltage.

Learning Outcomes 

  • Review the basic electrical formulas associated with grounding and stray voltage
  • Discuss how transient events create hazards which may be dangerous to the public and utility personnel, as well as damage equipment
  • Review Section 9 of the National Electric Safety Code and learn acceptable grounding methods
  • Discuss the definitions of commonly used terms such as “effectively grounded” and “bonded”
  • Identify ground resistance measurement for both substations and the distribution system
  • Discuss the effects of electricity on biological objects (animals and human beings)
  • Discuss the definition of stray voltage
  • Assess stray voltage trouble shooting and mitigation techniques
  • Review various stray voltage scenarios

Credits

AP_Logo

EUCI has been accredited as an Authorized Provider by the International Association for Continuing Education and Training (IACET).  In obtaining this accreditation, EUCI has demonstrated that it  complies with the ANSI/IACET Standard which is recognized internationally as a standard of good practice. As a result of their Authorized Provider status, EUCI is authorized to offer IACET CEUs for its programs that qualify under the ANSI/IACET Standard.

EUCI is authorized by IACET to offer 1.0 CEUs for this event.

Requirements For Successful Completion Of Program 

You must be logged in for the entire presentation and send in the evaluation after the course is completed. 

Instructional Methods 

PowerPoint presentations, case studies, and workshop exercises will be used in this program. 

Who Should Attend

>Electric Engineering professionals and technicians seeking a contemporary overview of distribution grounding practices and stray voltage issues.

Agenda

Tuesday, March 16, 2021 : Central Time

8:45 – 9:00 a.m. :: Log In

9:00 a.m. – 4:30 p.m. :: Course Timing 

12:30 – 1:15 p.m. :: Lunch Break


Engineering Formulas Relevant to Grounding

  • Ohm’s Law
  • Kirchhoff’s Voltage and Current Laws
  • Alternating Current
  • Impedance Model
  • Three Phase Power Systems

Transient Event on the Distribution System

  • Lightning Events
    • Surge Arrester Operation
  • Line to Ground Faults
    • Temporary Over Voltage (TOV)

Grounding Methods

  • NESC 2017 Section 9
    • Point of Connection
    • Method of Connection
    • Grounding Electrodes
    • Separation of Ground Conductors

Grounding Definitions

  • Effectively Grounded – Per NEC
  • Bonded – Per NEC
  • Step/Touch

Common Grounding Practices

  • Distribution System
    • Ground Resistance Measurements
      • Earth Ground Clamp Meters
    • Substation
      • Ground Grids
        • Soil Resistivity

Effects of Electricity on Biological Objects

  • Humans
  • Animals
  • Threshold of Perception
  • Threshold of Fatality

Wednesday, March 17, 2021 : Central Time

8:45 – 9:00 a.m. :: Log In

9:00 a.m. – 12:00 p.m. :: Course Timing


Stray Voltage Definition

  • Per IEEE Working Group 1695
  • Stray Voltage vs. Contact Voltage
  • Influential Factors on Stray Voltage

Stray Voltage Mitigation Techniques

  • Phase Balancing
  • Power Capacitor Bank Issues
  • Deteriorated Neutrals
  • Neutral Isolators

Stray Voltage Scenarios

  • Swimming Pools
  • Shower and Faucets
  • Farms
  • Fences and Gates
  • Marina and Boat Docks

Instructors

Jerry Josken, Senior Consultant, Pike Engineering

Jerry holds a BS in Electrical Engineering Technology from the Milwaukee School of Engineering and a MBA from North Central College. During his 30+ year career with Eaton’s Cooper Power Systems, Jerry served in a variety of engineering capacities. Past leadership positions include Chair of IEEE Rural Electric Power Conference (2012) and GLEMS Distribution Equipment /Controls (2013-2014). Presently, Jerry coordinates Pike Engineering Professional Development Program.


Keary Dosier, Director of System Planning and Grid Analytics, Pike Engineering

 Keary holds a BS degree in Electrical Engineering from NC State University. He is a Director for the System Planning and Grid Analytics division of Pike Engineering, where he has spent 16 years performing engineering studies and delivering solutions for large and small electric utilities across the United States. Keary has spent his career focused on distribution system planning, reliability, protection, DER integration and performance optimization engineering analysis. He has also performed several stray voltage mitigation studies, and in 2004 he co-authored an IEEE PES paper “Stray Voltage: Causes, Impacts, and Mitigation” on the subject.

Online Delivery

We will be using Microsoft Teams to facilitate your participation in the upcoming event. You do not need to have an existing Teams account in order to participate in the broadcast – the course will play in your browser and you will have the option of using a microphone to speak with the room and ask questions, or type any questions in via the chat window and our on-site representative will relay your question to the instructor.

  • You will receive a meeting invitation will include a link to join the meeting.
  • Separate meeting invitations will be sent for the morning and afternoon sessions of the course.
    • You will need to join the appropriate meeting at the appropriate time. 
  • If you are using a microphone, please ensure that it is muted until such time as you need to ask a question.
  • The remote meeting connection will be open approximately 30 minutes before the start of the course. We encourage you to connect as early as possible in case you experience any unforeseen problems.

Register

Please Note: This event is being conducted entirely online. All attendees will connect and attend from their computer, one connection per purchase. For details please see our FAQ

If you are unable to attend at the scheduled date and time, we make recordings available to all registrants for three business days after the event

Event Standard RateAttendees
Single Connection - Electric Distribution Grounding & Stray VoltageUS $ 1195.00
Pack of 5 connectionsUS $ 4,780.00
Pack of 10 ConnectionsUS $ 8,365.00
Pack of 20 ConnectionsUS $ 14,340.00
Call us at 303.770.8800 if you have any specific questions on the volume discounts
* all other discounts do not apply to license packs

By registering I indicate I agree with EUCI's privacy policy and understand I may receive emailed reports, articles, event invitations and other information related to products and services from EUCI and any of our business partners. I understand I may unsubscribe at any time by clicking the link included in emails.

Cancellation Policy

Your registration may be transferred to a member of your organization up to 24 hours in advance of the event. Cancellations must be received on or before February 12, 2021 in order to be refunded and will be subject to a US $195.00 processing fee per registrant. No refunds will be made after this date. Cancellations received after this date will create a credit of the tuition (less processing fee) good toward any other EUCI event. This credit will be good for six months from the cancellation date. In the event of non-attendance, all registration fees will be forfeited. In case of conference cancellation, EUCIs liability is limited to refund of the event registration fee only. For more information regarding administrative policies, such as complaints and refunds, please contact our offices at 303-770-8800

By clicking Accept or closing this message, you consent to our cookies on this device in accordance with our cookie policy unless you have disabled them. more information

By clicking Accept or closing this message, you consent to our cookies on this device in accordance with our cookie policy unless you have disabled them. You can change your cookie settings at any time but parts of our site will not function correctly without them. We use cookies during the registration process and to remember member settings.

Close